Two numbers describe this switch, and both matter. It carries 250 amps continuously, and it will take 360 amps for the short bursts that a windlass, thruster or hydraulic pack demands. Add a yellow housing and you get a master isolate that can be picked out instantly on a busy panel or inside a dark battery compartment.
Operation stays deliberately basic: rotate to ON, rotate to OFF, with a detent stop at each end. No intermediate selector position, no combined-bank link, nothing that needs explaining to a charter guest or a new crew member.
Maximum working voltage is 32 volts, so the same unit suits 12V and 24V installations. Studs accept conventional ring lugs, and the body mounts through a flat flange onto a panel, bulkhead or battery box wall.
| Continuous rating | 250A — sustained loads such as lighting, pumps, electronics and charging |
|---|---|
| Intermittent rating | 360A — short bursts, typically windlass, thruster or motor start |
| Maximum voltage | 32V DC |
| Positions | ON-OFF, two-position rotary |
Treat the intermittent figure as a window, not a habit. It exists so a burst load can pass without damage, and it assumes the cable, lugs and stud torque are all correct for the current involved.
| Model | MT049 |
|---|---|
| Brand | NEKEKE |
| Device Type | Battery isolator / master disconnect |
| Operation | ON-OFF, two-position rotary |
| Continuous Rating | 250 Amps DC |
| Intermittent Rating | 360 Amps DC |
| Maximum Voltage | 32V DC |
| Color | Yellow |
| Mounting | Panel mount, fixing flange |
| Application | Boat, yacht, RV, car, light commercial |
| Origin | China |
| Compliance | CE, RoHS |
Shut down heavy consumers before moving the dial. Opening a 250A circuit under load will draw an arc and damage the contacts. Keep the yellow housing clean so the colour stays easy to see, check nut torque each season, and replace cable with corroded lugs rather than retightening it.
Short bursts such as a thruster or windlass run. Sustained loads must stay at or below 250A.
Yes, the maximum working voltage is 32V DC, which covers 12V and 24V installations.
Other moulding colours can be produced against your sample or drawing, confirmed before production.
No. It is a single-circuit ON-OFF isolator; separate banks need a selector model.