| Model: | MT068 | Voltage: | DC 12V-48V |
|---|---|---|---|
| Continuous Rating: | 250A DC | Cranking Rating: | 1000A DC |
| Operation: | ON-OFF, Two-position Rotary | Material: | ABS Housing + Copper Current Path |
| Mounting: | Panel Or Bracket Fixing | Application: | Boat, Yacht, RV, Car, Off-grid Solar |
| Compliance: | CE, RoHS | ||
| Highlight: | Two-Position Rotary Battery Isolator,250A Continuous 1000A Cranking Switch,12V-48V DC Marine Disconnect Switch |
||
A battery master switch earns its place the day someone has to kill the power in a hurry. The MT068 answers that moment with a two-position rotary head that clicks into ON or OFF and stays there — no half-turned dial, no guessing which way is dead. Under the housing, a solid copper bridge carries 250A continuously and swallows 1000A for the few seconds an engine or bow thruster needs to crank.
What makes this part worth stocking is the voltage spread: DC 12V through 48V from a single SKU. A dinghy tender, a 24V workboat, a 36V golf car and a 48V electric outboard all take the same switch, so a distributor carries one box instead of four and the wrong-part return disappears from the counter.
| Model | MT068 |
|---|---|
| Switching action | ON-OFF, two-position rotary with positive detent |
| Working voltage | DC 12V – 48V |
| Continuous current | 250A DC (permanent load) |
| Cranking current | 1000A DC (engine-start burst only) |
| Housing | Moulded ABS, sealed body joint |
| Current path | Solid copper contact bridge |
| Terminals | Heavy-duty studs for closed ring lugs |
| Fixing | Panel or bracket, rear mounting base |
| Conformity | CE, RoHS |
Sales sheets quote the big cranking number because it looks impressive. Wire to it and the switch will discolour and eventually weld. The table below is the order to think in.
| Continuous — 250A DC | This is the number you size the cable against. The load may sit here all day without a rise in stud temperature. |
|---|---|
| Cranking — 1000A DC | Reserved for the seconds an engine or thruster pulls. Treat it as a burst, never as a working load. |
| Voltage — DC 12V to 48V | One part number covers 12V tenders, 24V trucks, 36V carts and 48V outboards, so stock stays simple. |
| First week in service | Re-torque the stud nuts and look for heat tint on the terminals. |
|---|---|
| Every month | Feel the studs after a loaded run and wipe the salt film off the housing. |
| Start of each season | Cycle ON-OFF several times, inspect lugs for corrosion, check cable insulation. |
| After any electrical fault | Replace a cable with a damaged lug. Retightening a heat-affected joint is not a repair. |
Model MT068, ON-OFF two-position rotary, ABS housing with copper current path, rated 250A continuous and 1000A cranking at DC 12V–48V. Minimum order 5 pieces, price quoted against quantity and packing. Standard production runs 30 days from deposit, T/T or Western Union with 30% down and the balance before shipment. Units ship in export cartons; pallet quantities and mixed containers can be quoted on request.
Yes. The unit is rated DC 12V–48V at 250A continuous, which covers most 48V marine and off-grid installations. Confirm the bank short-circuit current with your battery supplier before commissioning.
Two MT068 units give independent isolation of start and house banks, which is what surveyors usually prefer for a hard break on each circuit.
No. Shut the engine or drive controller down first. Breaking a loaded DC circuit draws an arc and pits the contacts.
It should not. The head has a positive stop at both ends; a quick check at each service interval is still good practice.
Moulded marking and dial artwork can be produced to your drawing once the specification and order quantity are agreed.
Send us your system voltage, cable cross-section and the number of banks you need to isolate, and we will confirm the right MT068 configuration and packing for your order.