| Model: | MT134-B | Operation: | ON-OFF Rotary Selector |
|---|---|---|---|
| Maximum Voltage: | DC 32V | Continuous Rating: | 350A |
| Intermittent Rating: | 600A | Cranking Rating: | 1,200A |
| Studs: | 3 (bank 1, Bank 2, Common Output) | Material: | ABS Housing + Copper Current Path |
| Application: | Dual Battery Boat, Yacht, RV, Truck | Compliance: | CE, RoHS |
| Highlight: | OFF-1-BOTH-2 Battery Selector Switch,Three Stud Marine Isolator 350A,1200A Cranking Dual Bank Switch |
||
Most people buy a selector to switch between two batteries. The MT134 also earns its keep as a diagnostic tool: with OFF-1-BOTH-2 positions on a single dial, you can run each bank on its own under load and find out which one is tired before it strands you.
Electrically it is a workhorse — 350A continuous, 600A intermittent and 1,200A cranking at DC 32V — with three studs, a copper contact bridge and a sealed ABS body. Two banks in, one common output out, and a dial that tells you where you are.
| Model | MT134-B |
|---|---|
| Operation | ON-OFF rotary selector |
| Maximum voltage | DC 32V |
| Continuous rating | 350A |
| Intermittent rating | 600A |
| Cranking rating | 1,200A |
| Studs | Three — bank 1, bank 2, common output |
| Housing | ABS, sealed body joint |
| Current path | Copper contact bridge |
| Compliance | CE, RoHS |
| Dial feel | Each stop should be crisp. A soft detent means the mechanism is worn and the dial may not sit fully in position. |
|---|---|
| Stud temperature | Warm after a loaded run is normal. Too hot to hold points at a lug, not the switch. |
| Body joint | Look for gaps or salt film after a season; the sealed joint is what keeps the contact set clean. |
| Cable insulation | Cracked insulation near a lug is a sign of heat, and heat usually starts at the joint. |
MT134, OFF-1-BOTH-2 selector, DC 32V maximum, 350A continuous, 600A intermittent and 1,200A cranking, three studs. There is no minimum order quantity: single units, samples and mixed containers are all accepted, with pricing quoted against quantity and packing. Standard production takes 30 days from deposit, T/T or Western Union, 30% down and the balance before shipment. Carton packed; pallet lots quoted separately.
No. Shut the engine or charger down before moving the dial. Breaking a loaded DC circuit draws an arc and can damage an alternator.
Yes, when a single alternator or charger is running. Do not leave the dial there permanently, because a weak bank will pull the good one down.
Check the thruster's own duty cycle. The 600A intermittent rating covers short bursts, but the continuous total on the circuit must stay under 350A.
No. DC 32V is the maximum, which suits 24V nominal systems with charging headroom.
No MOQ on the MT134. Single units, samples and mixed containers are accepted, priced against quantity and packing.
Send your bank sizes, panel cut-out and cable size and we will confirm the MT134 configuration, packing and freight. No minimum quantity required.