| Model: | MT081 | Operation: | OFF-1-BOTH-2 Rotary Selector |
|---|---|---|---|
| Maximum Voltage: | DC 32V | Continuous Rating: | 350A |
| Intermittent Rating: | 600A | Cranking Rating: | 1,200A |
| Material: | ABS Housing + Copper Current Path | Studs: | 3 (bank 1, Bank 2, Common Output) |
| Application: | Dual Battery Boat, Yacht, RV, Truck | Compliance: | CE, RoHS |
| Highlight: | OFF-1-BOTH-2 Dual Battery Selector,DC32V 350A Marine Isolator Switch,1200A Cranking Battery Selector |
||
A selector switch is really a small battery management system: three studs, four positions, and every decision about which bank feeds the boat. The MT081 handles that job at DC 32V with 350A continuous, 600A intermittent and a 1,200A cranking burst — sized for twin-bank 24V installations where the selector is also the master switch.
The dial order is marked OFF-1-BOTH-2. Putting OFF at the end of travel is deliberate: the position you need in a hurry is the one you reach by turning the dial all the way, not one you have to find in the middle of the scale.
| Model | MT081 |
|---|---|
| Operation | OFF-1-BOTH-2 rotary selector |
| Maximum voltage | DC 32V |
| Continuous rating | 350A |
| Intermittent rating | 600A |
| Cranking rating | 1,200A |
| Studs | Three — bank 1, bank 2, common output |
| Housing | ABS with sealed body joint |
| Current path | Copper contact bridge |
| Compliance | CE, RoHS |
| Continuity by position | Buzz each stud pair in every dial position against the position table. A selector that reads correctly but connects wrongly will destroy an alternator. |
|---|---|
| Stud torque | Check all three studs with a torque wrench, not by feel. Panel builders who skip this step find the loose one a season later. |
| Dial detent | Cycle through all four positions several times and confirm each stop is positive and repeatable. |
| Body and seal | Inspect the joint for gaps before packing; a selector that leaks will not survive a salt-water engine bay. |
MT081, OFF-1-BOTH-2 selector, DC 32V maximum, 350A continuous, 600A intermittent and 1,200A cranking. There is no minimum order quantity: single units, samples and mixed containers are all accepted, with pricing quoted against quantity and packing. Standard production takes 30 days from deposit, paid by T/T or Western Union with 30% down and the balance before shipment. Units ship in cartons; pallet lots quoted separately.
Change position only after the engine or drive controller is shut down. Breaking a loaded DC circuit draws an arc that pits the contacts and can damage an alternator.
For house loads and a single start circuit, yes. Add up everything that can run at once, then compare with the continuous rating — not with the cranking figure.
It keeps the emergency position at the end of travel, where it can be found by feel in the dark. The order is OFF-1-BOTH-2 as marked on the face.
Yes. Send your panel dimensions and cable schedule and we will return a dimensioned drawing for approval before production.
No MOQ on the MT081. Single units, samples and mixed containers are accepted, priced against quantity and packing.
Send your bank sizes, cable schedule and panel drawing and we will confirm the MT081 configuration, packing and freight. No minimum quantity required.