| Model: | MT067 | Operation: | ON-OFF, Two-position Rotary |
|---|---|---|---|
| Voltage: | DC 12V-48V | Continuous Rating: | 250A DC |
| Cranking Rating: | 1000A DC | Material: | ABS Housing + Copper Current Path |
| Mounting: | Flat Panel Or Bracket, Four-point Base | Application: | Boat, Yacht, RV, Car, Off-grid Solar |
| Compliance: | CE, RoHS | ||
| Highlight: | Rotary Master Disconnect 250A,Dual Bank Battery Cut Off,ABS Body Copper Bridge Contacts |
||
If you have ever climbed into a locker to find a corroded selector with four detents and no clear OFF, the MT067 is the answer to that. It has exactly two positions. Turn it one way and everything downstream is dead; turn it back and the bank is live again. There is no third detent to remember and no key to lose.
Under the housing, a copper bridge carries 250A continuously and absorbs the 1000A surge of an engine start. The shell is moulded ABS, chosen because it keeps its shape when a heavy lug is torqued onto the stud — a soft housing will bow, the stud will tilt, and the joint will heat up. That failure mode is what this design avoids.

| Model | MT067 |
|---|---|
| Type | Rotary master disconnect, two positions (ON / OFF) |
| Working voltage | DC 12V – 48V nominal |
| Continuous current | 250A DC |
| Cranking current | 1000A DC (start duration only) |
| Housing | ABS, spray and UV resistant |
| Current path | Copper bridge and copper-plated studs |
| Fixing | Flat panel or bracket, four-point base |
| Compliance | CE, RoHS |
Buyers sometimes ask why a switch that starts a 1000A engine is only labelled 250A. The two figures describe two different jobs. 250A is the current it can sit at all day long without the contacts turning blue. 1000A is the half-second inrush of a starter motor, gone before the metal has time to heat. Design the cable around the 250A number, and let the 1000A figure do the starting.
Reverse the logic — pick cable for 1000A and assume the switch can carry it continuously — and the contacts will pit, resistance will climb, and the switch becomes the hottest point in the circuit.

Almost every field failure in a high-current DC switch traces back to the termination, not the contact set. Work through this in order and the joint will outlast the rest of the installation.

A disconnect switch is at its most useful when a boat or a camper is not being used. Leave the dial at OFF through the off-season, and the self-discharge and parasitic drain stop fighting the charger. Before lay-up, spray the studs with a corrosion inhibitor, and at recommissioning wipe the housing down and cycle the dial a few times so the contacts clean themselves before any real current flows.
It is a simple ON/OFF disconnect. Always bring the load to zero before turning the dial.
The ABS housing resists spray and UV; keep the studs coated and check them at the start of each season.
Yes, provided the base sits on a rigid flat surface and the dial has room to turn.
This is a single-circuit switch. For two banks, use one switch per bank or a dual-bank selector.
Moulded or printed dial legends and branded cartons can be arranged against a written trademark authorisation.
Tell us your system voltage, continuous load and cable size, and we will confirm whether the MT067 is the right frame for the job or point you to a larger one.